Multi-Agent AI System for Radiology Report Structuring and Quality Assurance with Independent Radiologist Evaluation
Mirrored from arXiv — NLP / Computation & Language for archival readability. Support the source by reading on the original site.
Computer Science > Computation and Language
Title:Multi-Agent AI System for Radiology Report Structuring and Quality Assurance with Independent Radiologist Evaluation
Abstract:Purpose: To develop and evaluate a locally deployed multi-agent AI system for radiology report structuring and quality assurance. Materials and Methods: This retrospective study included 638 radiology reports from CT examinations of the chest, abdomen, and pelvis dictated by 15 board-certified radiologists in 2023 and 2024. A multi-agent AI pipeline was developed to perform report structuring and quality assurance (QA). The system structured the report into standardized anatomical sections at the sentence level using regex rules and local large language models. It also detected mismatches between the Findings and Impression sections, or within sections; gender-anatomy conflicts; and undocumented communication of critical findings. Two board-certified radiologists independently evaluated a 45-report subset. Results: The multi-agent system structured the Findings sections of all reports (22,270 sentences) into a predefined anatomical format while retaining the original report content. The system flagged 90 (14.1%) reports, most commonly for section mismatches (80 reports, 12.5%). In the radiologist evaluation, both reviewers agreed that 31 (69%) were correctly restructured, 2 reports (4%) were incorrectly restructured, and disagreed on the remaining 12 reports (27%). Both reviewers agreed that no clinically important information was omitted and no fabricated content was introduced. Overall QA performance was rated as "excellent" or "good" in 84% of the evaluated reports, with the remaining reports rated as "fair". Conclusion: A locally deployed multi-agent AI system combined radiology report structuring and quality assurance within a single workflow. The system demonstrated favorable performance in radiologist evaluation. Such systems may support standardization of reporting and quality assurance in radiology practice.
| Comments: | 14 pages, 2 figures, 4 tables |
| Subjects: | Computation and Language (cs.CL) |
| Cite as: | arXiv:2608.18072 [cs.CL] |
| (or arXiv:2608.18072v1 [cs.CL] for this version) | |
| https://doi.org/10.48550/arXiv.2608.18072
arXiv-issued DOI via DataCite (pending registration)
|
Access Paper:
- View PDF
- HTML (experimental)
- TeX Source
References & Citations
Bibliographic and Citation Tools
Code, Data and Media Associated with this Article
Demos
Recommenders and Search Tools
arXivLabs: experimental projects with community collaborators
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.
More from arXiv — NLP / Computation & Language
-
Recipes for Steering and Scaling LLMs via Sampling
Aug 28
-
Can a Model Catch Its Own Hallucinations for Free?: Label-Free Doubt Signals Hold Their Own Against a Labelled Dataset for Abstention
Aug 28
-
FIRSTPASS: A Multi-Domain, Multi-Round Peer Review Dataset Grounded in Real Editorial Outcomes
Aug 28
-
Interpretable, Fairly Evaluated Automated L2 Speaking Assessment that Beats the Single-Human Ceiling and Why Pause Encoding Does Not Change LLM Fluency Scores
Aug 28
Discussion (0)
Sign in to join the discussion. Free account, 30 seconds — email code or GitHub.
Sign in →No comments yet. Sign in and be the first to say something.